Pre-sales consultation
+86-15810684257
Email:info@manthink.cn
cnen
EN

SE81Air quality monitoring product specification

1. Product Introduction

1.1 Product Description

SE81 is a wireless air quality detector, which can realize timing sampling and upload air quality information to the monitoring platform; It supports LoRaWAN and LinkWAN protocols. You can set the sampling and reporting cycle on the mobile phone or the platform.

1.2 Application fields

  • Office environment
  • Smart Home
  • Smart Building
  • Smart Agriculture

1.3 Main features

  • Simultaneous detection of PM2.5, CO, formaldehyde, temperature, humidity, light and VOC
  • Highlight LED dot matrix display
  • Supports configuration of wireless handheld devices and offline data.
  • Modular design for easy installation and replacement

2. Product parameters

2.1 Exterior

2.2 Electrical parameters

Operating voltage

AC220V

Operating temperature

-40℃ ~ 85℃

Working humidity

0%~90%RH

2.3 RF parameters

Frequency range

470-510MHz

863-928 MHz (optional)

Transmit power

5 ~ 20dBm

Receiving sensitivity

<-139dBm

@ 292bps

Antenna Type

Internal or external antenna (optional)

Data transmission rate

292 ~ 5.4kbps

Modulation mode

LoRa

Supported LoRaWAN frequency bands

CN470/EU433/EU868/AU915/AS923/KR920

Supported LinkWAN frequency bands

CN470/AS923

2.4 collection indicators

Temperature

Measurement range

-20 ~ 50℃

Measurement accuracy

± 2℃

Resolution

0.1 ℃

Humidity

Measurement range

10%~90%RH

Measurement accuracy

±5%RH

Resolution

0.1%RH

Formaldehyde

Measurement range

0~3mg/m³

Measurement accuracy

± 5%

Resolution

0.01mg/m³

Light

Measurement range

0 ~ 999lux

Measurement accuracy

± 5%

Resolution

1lux

Carbon dioxide

Measurement range

0 ~ 5000ppm

Measurement accuracy

±(50ppm + 5% display value)

Resolution

1ppm

PM2.5

Measurement range

0~1000μg/m³

Measurement accuracy

± 10%

Resolution

1μg/m³

2.5 structure dimension

Length:86mm Screen area size:

width :35mm Length:75mm width :36mm

height :86mm Machine weight:<200g

3. Instructions

3.1 Installation Instructions

Connect the sensor power plug to the power supply

3.2 View uploaded data

  1. SE81 power on and start working normally
  2. The gateway is powered on at the specified location and connected to the network.
  3. Use NMS to View upstream data